Anatomy of a CTO CTO Crossing involves passage of three segments: · Proximal Cap · Mid-Occlusion SIDEKICK® SUPPORT CATHETER CROSSER® CTO RECANALIZATION CATHETER HIDDEN COLLATERAL CALCIFIC PLANE ANGLED TIP OF SUPPORT CATHETER ALLOWS FOR IMPROVED STEERABILITY TOWARDS FLUSH OCCLUSIONS OR LESIONS ON AN ANGLE
Challenges of a CTO · CTO procedure failures are primarily due to the inability to:1 LENGTHY PROCEDURES RADIATION EXPOSURE PERIPROCEDURAL COMPLICATIONS REPEAT INTERVENTION · Navigate side branches · Re-enter distal true lumen · Failure to cross lesions, with possible procedure failure, may lead to important burdens such as lengthy procedures, increased radiation exposure, periprocedural complications, and repeat intervention2,3 · Clinical literature has shown CTO crossing success rates of 5% to 66% with primary wire-catheter1 · This may result in sub-intimal deflection and subsequent.
The Workhorse 5F Catheter The CROSSER® 14S Catheter is a frontline therapy that enables central lumen crossing and maximizes therapeutic options for CTO recanalization via atherectomy. Focused Efficiency for Highly Calcified Lesions The small CROSSER® S6 Catheter tip focuses vibrational energy providing greater efficiency. The flexible design of the CROSSER® S6 Catheter facilitates deliverability to small and tortuous vessels. CROSS CHALLENGING LESIONS VIA ATHERECTOMY
Capital Equipment Generator The reusable, 21kHz CROSSER® Generator converts AC power into high frequency current. Piezoelectric crystals within the transducer convert high frequency current into vibrational energy. The physician controls the procedure and pace of the CROSSER® Generator and FLOWMATE® Injector with a single foot switch. Injector The performance of the CROSSER® Catheter is optimized by precise activation and saline delivery. The integrated saline injector has pre-set settings for a flow rate of 18ml/min and can be operated by one person for added convenience. 150 ML STERILE.
Disposable Devices Support Catheter Features • Stainless steel, braided shaft construction enables greater push and torquability* STRAIGHT TAPERED ANGLED TAPERED • Angled tip allows for improved steerability towards flush occlusions or lesions on an angle More Options The various tip stiffness levels of the PORTER® Delivery Guidewire provide precise steerability with 1:1 torque transmission. The unique hydrophilic coating of the PORTER® Guidewire provides enhanced trackability in tortuous anatomy. The SEEKER® Crossing Support Catheter expands treatment possibilities by combining optimal.
Enhance Your Procedure with the GeoAlign® Marking System The GeoAlign® Marking System is a non-radiopaque ruler on the catheter shaft measured from the distal tip. These markings are designed for simplified length measurement between two intravascular points. During repeat catheter placement, the GeoAlign® Marking System is designed to help increase procedure efficiency and reduce radiation exposure by minimizing fluoroscopy time. DISTANCE FROM THE DISTAL TIP OF CATHETER MARKER BANDS DENOTED EVERY 1 CM CROSSER + GeoAlign CTO Recanalization System Marking System ® INTRAVASCULAR MEASUREMENT.
Ordering Information Catheters & Capital Equipment Adjunctive Devices CROSSER® CTO Recanalization Catheters Description Length (cm) Platform RX 106 ® OTW CROSSER Catheter 14S RX 146 OTW 106 no wire CROSSER® Catheter S6 154 no wire CROSSER® Generator / FLOWMATE® Injector Description ® CROSSER Generator FLOWMATE® Injector FLOWMATE® Procedural Kit (5/box) Product Code GEN200 INJ100 INJKIT SIDEKICK® Support Catheters Length (cm) Shape Straight Straight Tapered 70 Angled Angled Tapered Straight Straight Tapered 110 Angled Angled Tapered FLOWMATE® Injector is intended for use with the CROSSER®.
CROSSER® CTO Recanalization Catheter Indications: The C ROSSER® Recanalization System is indicated to facilitate the intra-luminal placement of conventional guidewires beyond peripheral artery chronic total occlusions via atherectomy. The C ROSSER® Catheter is only intended for use with the C ROSSER® Generator. Refer to the C ROSSER® Generator Manual of Operations for proper use. Contraindications: The device is contraindicated for use in carotid arteries. Warnings and Precautions: 1) The C ROSSER® Recanalization System should only be used by individuals trained in percutaneous transluminal.